Providing you the best range of honeywell hm d240cmo ul single output module, honeywell morley mi dcmo control single output module, fire alarms and addressable fire alarm control panel with effective & timely delivery.
₹ 2700 Get Latest Price
Phase | Dual Phase |
Power Supply | 24 VDC |
Monitoring Parameters | Temperature |
Brand | Honeywell |
Display Type | Analog |
Model Name/Number | HM D240CMO Ul |
Fire Projects recommend the HM-D240CMO-UL Addressable Relay Module provides the system with a dry contact output for activating a variety of auxiliary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis.
The HM-D240CMO-UL may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power.
• The face plate is made of off-white, heat resistant plastic
• Controls include two rotary switches for direct-dial entry of address-setting
• The HM-D240CMO-UL is configured for a single Class B Notification Appliance Circuit
• The HM-D240CMO-UL provides two Form-C dry contacts that switch together
₹ 2800 Get Latest Price
Type | Addressable |
Relay Outputs | Alarm Relay |
Wireless Frequency | 50 Hz |
Shape | Square |
Mounting Type | Wall |
Control Keys | Evacuate |
The Morley-IAS MI-DCMO control output module is used with the ZX series of intelligent control panels to provide either a single alarm circuit or Form C relay. The MI-DCMO can be used to operate dry contacts for door holders, air handling unit shut down or other similar functions. Optionally the module can be used to supervise wiring to the output load providing monitoring of the external load voltage or power supply.
If the monitored voltage falls below threshold then a fault condition will be indicated. Each MI-DCMO uses one of the ninety-nine possible module addresses available on a loop. It responds to regular polling from the control panel indicated by a pulsing LED every successful communication. On command from the control panel the MI-DCMO will disconnect the supervision and connect the external power supply across the load. The disconnection of the supervision provides a positive indication to the control panel that the relay is activated. The MI-DCMO has a built-in isolator which may be switched out if required.
Key Features:
DIN rail mounting option
Surface mounting option
Tri-colour LED status indication
Built-in Short Circuit Isolators
Visible Address selector switches
LED status visible in 2 planes
Plug in connectors
Approved to GEA GEI 1-082 and CEA GEI 1-084